XML Meta-DTD Definition for NXsensor.xml

This follows the XML Meta-DTD Definition format and can be downloaded from http://svn.nexusformat.org/definitions/tags/PRE_NXDL/base_classes/NXsensor.xml

<?xml version="1.0" encoding="UTF-8"?>
<!--
URL:     http://www.nexus.anl.gov/classes/xml/NXsensor.xml
Editor:  NIAC
$Id: NXsensor.xml 4 2005-07-19 04:10:26Z rio $

This class describes a sensor used to monitor an external condition - the
condition itself in described in NXenvironment
-->
<NXsensor name="{Name of sensor}">
	<model type="NX_CHAR">
		{Sensor identification code/model number}?
	</model>
	<name type="NX_CHAR">
		{Name for the sensor}?
	</name>
	<short_name type="NX_CHAR">
		{Short name of sensor used e.g. on monitor display program}?
	</short_name>
	<attached_to type="NX_CHAR">
		{ where sensor is attached to ("sample" | "can") }?
	</attached_to>
	<NXgeometry name="">
		{Defines the axes for logged vector quantities if they are not the global instrument axes}?
	</NXgeometry>
	<measurement type="NX_CHAR">
		{ what we measure "temperature | pH | magnetic_field | electric field | conductivity | resistance | voltage | pressure | flow | stress | strain | shear | surface_pressure" }?
	</measurement>
	<type type="NX_CHAR">
		{ The type of hardware we use for the measurement e.g. Temperature: "J | K | T | E | R | S | Pt100 | Rh/Fe" pH: "Hg/Hg2Cl2 | Ag/AgCl | ISFET" Ion selective electrode: "specify species; e.g. Ca2+" Magnetic field: "Hall" Surface pressure: "wilhelmy plate" }?
	</type>
	<run_control type="NX_BOOLEAN">
		{ Is data collection controlled/synchronised to this quantity: 1=no, 0=to "value", 1=to "value_deriv1" etc.}?
	</run_control>
	<high_trip_value type="NX_FLOAT" units="{}">
		{Upper control bound of sensor reading if using run_control}?
	</high_trip_value>
	<low_trip_value type="NX_FLOAT" units="{}">
		{Lower control bound of sensor reading if using run_control}?
	</low_trip_value>
	<value type="NX_FLOAT[n]" units="{}">
		{nominal setpoint or average value - need [n] as may be a vector}?
	</value>
	<value_deriv1 type="NX_FLOAT[n]" units="{}">
		{Nominal/average first derivative of value e.g. strain rate - need [n] as may be a vector}?
	</value_deriv1>
	<value_deriv2 type="NX_FLOAT[n]" units="{}">
		{Nominal/average second derivative of value - need [n] as may be a vector}?
	</value_deriv2>
	<value_log type="NXlog">
		{Time history of sensor readings}?
	</value_log>
	<value_deriv1_log type="NXlog">
		{Time history of sensor readings}?
	</value_deriv1_log>
	<value_deriv2_log type="NXlog">
		{Time history of sensor readings}?
	</value_deriv2_log>
	<external_field_brief type="NX_CHAR">
		{ along beam | across beam | transverse | solenoidal | flow shear gradient | flow vorticity }?
	</external_field_brief>
	<external_field_full type="NXorientation">
		{For complex external fields not satisfied by External_field_brief}?
	</external_field_full>
</NXsensor>

Tabular Representation of XML Meta-DTD

(automatically generated from http://svn.nexusformat.org/definitions/tags/PRE_NXDL/base_classes/NXsensor.xml)

NXsensor

Name Type Description Attributes
modelNX_CHARSensor identification code/model number
nameNX_CHARName for the sensor
short_nameNX_CHARShort name of sensor used e.g. on monitor display program
attached_toNX_CHAR where sensor is attached to ("sample" | "can")
NXgeometryDefines the axes for logged vector quantities if they are not the global instrument axes
measurementNX_CHAR what we measure "temperature | pH | magnetic_field | electric field | conductivity | resistance | voltage | pressure | flow | stress | strain | shear | surface_pressure"
typeNX_CHAR The type of hardware we use for the measurement e.g. Temperature: "J | K | T | E | R | S | Pt100 | Rh/Fe" pH: "Hg/Hg2Cl2 | Ag/AgCl | ISFET" Ion selective electrode: "specify species; e.g. Ca2+" Magnetic field: "Hall" Surface pressure: "wilhelmy plate"
run_controlNX_BOOLEAN Is data collection controlled/synchronised to this quantity: 1=no, 0=to "value", 1=to "value_deriv1" etc.
high_trip_valueNX_FLOATUpper control bound of sensor reading if using run_control
units="{}"
low_trip_valueNX_FLOATLower control bound of sensor reading if using run_control
units="{}"
valueNX_FLOAT[n]nominal setpoint or average value - need [n] as may be a vector
units="{}"
value_deriv1NX_FLOAT[n]Nominal/average first derivative of value e.g. strain rate - need [n] as may be a vector
units="{}"
value_deriv2NX_FLOAT[n]Nominal/average second derivative of value - need [n] as may be a vector
units="{}"
value_logNXlogTime history of sensor readings
value_deriv1_logNXlogTime history of sensor readings
value_deriv2_logNXlogTime history of sensor readings
external_field_briefNX_CHAR along beam | across beam | transverse | solenoidal | flow shear gradient | flow vorticity
external_field_fullNXorientationFor complex external fields not satisfied by External_field_brief